There is no fixed replacement date: replace a boat battery when a capacity test shows it can no longer run your loads. For well-charged AGM and gel batteries that is often 5 to 8 years, much sooner in heat or with deep daily discharges. Lithium LiFePO4 batteries are rated for 2,500 to 5,000 cycles.
Battery makers don't give a service interval in months. They give a cycle life at a stated depth of discharge (DoD) and a design life at a stated temperature, and the years you get depend on how hard you use the bank. This guide translates those figures into practice, lists the signs that a battery is finished and explains why the charger matters as much as the battery. The figures are a guide: your battery's datasheet and your marine electrician's tests come first.
What the interval depends on
Four things wear out a battery, and none of them is the calendar on its own:
- Number of cycles. Every discharge and recharge uses up some life. A boat that spends nights at anchor cycles its house bank far more than one that lives on shore power.
- Depth of discharge. Shallow cycles last much longer. Lifeline recommends an average depth of discharge of no more than 50% of the battery's 20-hour rating, and suggests sizing the bank at twice the capacity you use.
- Charging. Undercharging lead-acid leads to sulphation, and Trojan warns that constant under- or overcharging "will damage the battery and shorten its life". See the charging section below.
- Heat. The biggest silent killer. Rolls expects "a cycle life reduction of ~50% for every 10 °C over 25 °C (77 °F)", and Lifeline gives the same rule of thumb for both calendar and cycle life.
Life by battery type
| Type | Cycle life as the maker states it | Design or expected life |
|---|---|---|
| Flooded lead-acid, premium deep cycle | Rolls Series 4500 (L16 case): 3,700 cycles at 50% DoD | Not stated as years; depends on maintenance and charging |
| Flooded lead-acid, starting / "maintenance-free" | Lifeline: calcium-alloy flooded batteries have "much lower" cycle life and "are no longer considered deep cycle" | No figure published |
| AGM | Victron AGM Deep Cycle: 400 cycles at 80% DoD, 600 at 50%, 1,500 at 30%. Trojan 31-AES: 1,200 cycles at 100% DoD | Victron: 7–10 years on float at 20 °C (68 °F). Lifeline: around 5–8 years with proper use |
| Gel | Victron Gel Deep Cycle: 500 cycles at 80% DoD, 750 at 50%, 1,800 at 30% | Victron: 12 years on float at 20 °C (68 °F) |
| Lithium LiFePO4 | Victron Lithium Smart: 2,500 cycles at 80% DoD, 3,000 at 70%, 5,000 at 50% (to 80% of rated capacity). Battle Born BB10012: 3,000–5,000 deep cycles, 100% usable DoD | No figure in years; set by cycles |
Figures from each maker's published datasheets and manuals; brand names belong to their owners. Nautify is not affiliated with any of them.
Victron also publishes what heat does to its lead-acid batteries on float service:
| Average temperature | AGM Deep Cycle | Gel Deep Cycle |
|---|---|---|
| 20 °C (68 °F) | 7–10 years | 12 years |
| 30 °C (86 °F) | 4 years | 6 years |
| 40 °C (104 °F) | 2 years | 3 years |
If the battery compartment runs warm through a long hot season, expect a life well below the 20 °C (68 °F) figure. Mount batteries away from the engine and exhaust where you can.
To turn cycles into years, count your cycles. A weekend boat that discharges its house bank to 50% about 100 times a year would use up a 600-cycle AGM in roughly six seasons; the same boat cruising at anchor every night for three months adds another 90 cycles a year. If your battery's datasheet gives no cycle rating, as is common for starting and dual-purpose batteries, the capacity test is the only real guide.
Signs a battery is due, and what happens if you skip it
Lifeline's own list of warning signs is short: voltage that drops under a light load, a battery that won't hold a charge after a full charging cycle, a failed load test, and age over 5 to 7 years. In practice, look for:
- Lights dim and the fridge or autopilot alarms soon after you switch off the charger or engine.
- Low resting voltage. Let the battery rest a few hours off charge. Lifeline gives about 12.5 V as roughly 75% charged for a 12 V AGM. Trojan's flooded T-105 datasheet gives 6.37 V full and 6.05 V at 50% for a 6 V battery, about 12.7 V and 12.1 V for a 12 V bank.
- Specific gravity (flooded batteries only). Rolls gives 1.255–1.275 at full charge and 1.180–1.200 at 50%, at 25 °C (77 °F), and asks owners to test every 45 to 60 days. A cell that reads well below its neighbours points to a failing battery.
- Slow cranking, especially on a cold morning.
- A cracked or damaged case. Lifeline says a battery whose case cracked after freezing "is no longer serviceable".
The capacity test is the deciding check. Lifeline's procedure: stabilise the battery at 20–30 °C (68–86 °F), charge it fully, discharge it at 25 A until it reaches 10.5 V and compare the minutes with its rated reserve capacity. Below 80%, try a conditioning charge and retest; below 50%, replace it, though you can set a higher threshold if you need more capacity. Lifeline notes that quick load testers and conductance meters "are not reliable" for measuring capacity.
If you skip it, a weak house bank means a flat battery at anchor, a dead fridge and electronics that reset when the voltage dips. A weak starting battery can leave you unable to start the engine. Lifeline also advises replacing a whole string together: a new battery wired to tired ones gets undercharged or overdischarged, and all of them age faster.
Charging decides how long they last
The wrong charging profile shortens battery life more than anything except heat.
- Lead-acid (flooded, AGM, gel) needs a three-stage charger (bulk, absorption, float) set to the battery type, with temperature compensation. Trojan, for example, asks for 0.005 V per cell less for every 1 °C above 25 °C. Lifeline warns that recharging too little makes the state of charge "walk down", "resulting in sulfation and premature failure".
- Gel is the most voltage-sensitive. Lifeline's manual cites a gel maker's claim that charging 0.7 V too high cuts cycle life by 60%, compared with a 23% reduction for its AGM at 1.0 V too high.
- Lithium needs a battery management system (BMS) and a charger set to its own voltages. Victron's Lithium Smart batteries must be connected to an external BMS, which switches off chargers and loads on a fault, and can only be charged between +5 °C and +50 °C (41–122 °F). Battle Born's internal BMS includes a low-temperature charge cut-off, and its manual says to disable temperature compensation and equalisation on the charger.
If you are adding solar, the controller needs the right profile too; see our guide to solar panels on a boat. For how a boat's electrical system fits together, including battery banks, isolators and fusing, read boat batteries and the electrical system.
How much it costs to replace boat batteries
Replacing a lead-acid or AGM house bank of two or three 100–120 Ah batteries, fitted, typically costs €500–1,500 excluding VAT. A lithium upgrade of 200–400 Ah, including the monitor, charging changes and fusing, runs €2,500–8,000. Both are broken down in our marine electrician cost guide, along with hourly rates and the price of an electrical survey.
If you'd rather have a local electrician test the bank before you buy, you can ask several marine electricians for a quote in one request.
Mi barco reminds you to check the batteries and electrics every 24 months; replace them when the check says so. You can change the interval in the app and add your own reminders, for example a capacity test before a long cruise or a specific-gravity check every two months on flooded batteries.
The battery check fits naturally into the rest of the yearly jobs: see our boat maintenance schedule.
In short
Replace boat batteries when a capacity test shows they can't run your loads, not on a fixed date. Well-charged AGM and gel usually last 5 to 8 years, and heat can halve that. Lithium is rated for thousands of cycles but needs a BMS and a lithium charging profile. Keep discharges shallow, charge with the right profile, and replace a bank as a set.